The first domain controller holds the PDC emulator role. Every other computer in the domain sets its clock from it, so it must take its own time from the internet.
Every computer in the domain keeps the same, correct time.
Sign-in fails when clocks drift more than five minutes apart.
Point the first domain controller at internet time servers and check it syncs.
Every name, address and value in this guide is an example. Replace them with your own.
Why time matters
Kerberos, the system that signs people in, refuses tickets when two clocks differ by more than five minutes. A drifting DC clock shows up as staff who cannot sign in and errors that mention trust or tickets.
Point it at internet time
w32tm /config /manualpeerlist:"uk.pool.ntp.org,0x8 time.windows.com,0x8" /syncfromflags:manual /reliable:yes /update Restart-Service w32time w32tm /resync /rediscover
| Part | Meaning |
|---|---|
| manualpeerlist | The time servers to ask, in order. |
| 0x8 | Ask them in client mode, which public time servers expect. |
| reliable:yes | Tells the domain this server is a trustworthy time source. |
Allow the time traffic
The firewall must let this server reach the internet on UDP 123. Block UDP 123 for pupil devices if you can; they take time from the DCs.
Check it
w32tm /query /status w32tm /query /source w32tm /stripchart /computer:uk.pool.ntp.org /samples:3 /dataonly
Done when
The source shows uk.pool.ntp.org or time.windows.com, and the stripchart offsets are under one second. "Local CMOS Clock" or "VM IC Time Synchronization Provider" means it is not working yet; see Problems and fixes in the Create the first domain controller guide.